Medical Equipment Portable Biphasic Defibrillator with 8'' High Resolution LCD Display
Model:ADM7000
Product Description
Display
Display Type: 8 inch high resolution LCD display
Sweep Speed: 25mm/sec
Information: HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.
Ilator
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.
ECG Monitoring
Patient Connection: 5-lead ECG cable, or 3-lead ECG cable, paddles.
Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor, user-selectable.
Smart Alarms: Beeper/voice prompts indicate shockable rhythm.
Recorder
Paper: 50mm thermal.
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution, thermal print head.
Print-out Modes: Manual or automatic, user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.
Battary
Type: Rechargeable, Ni-MH battery, 12V.
Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring.
Additional parameters will effect operating time with different functions.
AED Mode
AED Function: Auto analyze and charge X3 with programmable auto energy level selection, screen prompts, and voice prompts.
Shockable Rhythms: Ventricular fibrillation with amplitude >=200UV, ventricular tachycardia with rates >=140bpm,
and QRS complex wave duration >=140ms.
Charge Control: Control on device front panel, press key on paddle.
Prompts: Voice and visual prompts.
Manual Mode
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules. Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monito
Specification |
MB pacer (Optional) |
Type |
VVI |
Pulse Type |
rectangular,constant current |
Pulse Amplitude |
0 to 180 mA ± 10% or 5 mA (whichever is greater). |
Pacing Rate |
Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm) |
Multi-Function Electrode (MFE)Pads |
multipurpose defibrillation/pacing electrodes |
Pause |
Pacing pulse frequency reduced by a factor of 4 when activated |
Refractory Period |
NC(VVI demand do not have this specification) |
Pulse Width |
(20+ 1.5 ms) |
Output Protection |
Fully defibrillator protected and isolated |
Type of sensor |
By-pass |
Technical principle |
Non-dispersiveinfraredgas analysis NDIR |
Storage condition |
-40 °C to 70°C, <90% RH, non-condensing |
Operating conditions |
5 °C to 50 °C, 10 to 90% RH, non-condensing |
Ambient pressure |
55-115kPa |
Power supply |
5 V±5% (max ripple 200 mVp-p) |
TDP |
Typical value120mA Excursion calibration typical value280mA |
Range |
0-19.7% (0-150mmHg,or0-20kPa) |
Resolution |
O.lmmHg |
Accuracy |
0 - 40 mmHg ± 2 mmHg 41 - 70 mmHg ± 5% ofreading 71 -100 mmHg ± 8% of reading 101 -150 mmHg ± 10% of reading |
Respiratory rate |
2-150 BPM |
Respiratory rate measurement accuracy |
1% ±1BPM |
Specification |
MB_NIBP (Optional) |
Measurement unti: |
mmHg/kPa |
Measurement Range : |
Adult:10-270 mmHg/kPa |
|
Pediatric: 10-200 mmHg/kPa Neonatal: 10-135 mmHg/kPa |
Resolution |
1 mmHg |
Accuracy: |
Maximum mean error:5 mmHg Maximum standard deviations mmHg |
Type of sensor |
By-pass |
Technical principle |
Non-dispersive infrared gas analysis NDIR |
Storage condition |
-40 °C to 70°C, <90% RH, non-condensing |
Operating conditions |
5 °C to 50 °C, 10 to 90% RH, non-condensing |
Ambient pressure |
55-115kPa |
Power supply |
5 V ±5% (max ripple 200 mVp-p) |
TDP |
Typical value 120mA Excursion calibration typical value 280mA |
Range |
0-19.7% (0-150mmHg,or0-20kPa) |
Resolution |
O.lmmHg |
Accuracy |
0 - 40 mmHg ± 2 mmHg 41 - 70 mmHg ± 5% of reading 71 -100 mmHg ± 8% of reading 101 -150 mmHg ± 10% of reading |
Respiratory rate |
2-150 BPM |
Respiratory rate measurement accuracy |
1% ±1BPM |
Specification |
SPO2 Moudle (Optional) |
Measurement Range: |
30 -100%+2% between 80%-90%,Others ±5% |
Alarm Range |
User set high limit and low limit |
Alarm Accuracy |
±10 within setting values. |
Alarm Time Accuracy |
Less than 12 sec. |
Product Feature
Battery Level Indicator
To monitor the battery real time
Biphasic Technology
With impedance compensation More effective
Less Energy and less hurt to the heart
Internal Thermal Printer
50mm integrated thermal recorder
Data Storage
65 hours of all measured parameters
Paddle
Charging and shocking can be easily operated through according buttons
Quickly converted from adultto pediatric by removing theouter surface
FAQ
Q 1: Your company is manufacturer or trader?
A 1:We are one industry & Trade company. We have own investment in factory of xray machine, to invest in some good factory to strengh our own product supply chain is our long term strategy.
Q 2: What certificate do you have for products you supply?
A 2: All our products have ISO, 90% have CE, some FDA
Q 3: What is your Warranty for medical equipment?
A 3: Basically 14months after goods leave China. Our own manufactured Xray 24months warranty.
Q 4: What is your acceptable payment way?
A 4: T/T in advance, WEST UNION, MONEYGRAM, and L/C if needed.
Q 5:Can you do OEM for us?
A 5: Yes, we can. Some products with low value need quantity to do OEM.
Q 6: What is your MOQ?
A 6: For common equipment, 1pcs is MOQ. For consumables, we can discuss.