Customization: | Available |
---|---|
Certification: | CE, FDA, ISO13485 |
Display: | 12.1 Real Color TFT Screen |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | AD-12 |
Application Range | Adult/Pediatric/Neonatal/Medicin e/Surgery/ Operating Room/ICU/CCU |
Display | 12.1* real color TFT screen |
working environment conditions Temperature | Working temperature0-40ºC Working humidity≤85% |
Power supply voltage | AC 100~240V AC |
power frequency | 50/60Hz, maximum input power 70VA |
Built-in lithium battery | d.c11.1V not |
Product Size | 262*336*84mm |
product weight | 2.72kg |
Gain | X0.25,x0.5, x1,X2,Auto |
Waveform speed | 12.5mm/s,25mm/s,50mm/s |
Diagnosticmode | 0.05-130Hz Monitoring mode:0.5-40Hz Operation mode:1~20Hz |
Common Mode Rejection Ratio | Diagnosticmode:>90dB Monitoring mode:>100dB Operation mode:>100dB |
Electrode polarization voltage | ±300mV Input impedan ce≥5M |
DC biasvoltage | ±300mV |
Calibration signal | 1mV (peak-to-pea k), accuracy±5% |
ST segment detection measurement: Measurement range | -2.0mV-+2.0mV |
Measuring Range and Precision Range | Adult Systolic blood pressure40~270mmHg Diastolic blood pressure 10~215mmHg Mean blood pressure 20~235mmHg Static pressure range 0~300mmHg Static pressure precision ±3mmHg |
Pressure precision | Max. average error: ±5mmHgi Max stand ard devaton: 8mmHg |
Spo2 | Measuringrange0~100% Resolution 1% The accuncyis within the range of 70% to 100%, and the measurement error should be ±2%; In therange of 0% to 69%, the measurement error is undefined |
Pulse Rate | Measuringrange 30~300bpm Resolution 1bpm Accuracy±3bpm Updatetime ls |
Standard accessories | NIBP cuff&tube ECG cable & electrodes Sp02 sensor TEMP probe Lithium-ion battery Power cable Operator's manual |
Optional accessories | End-tidal CO2 (optional) Recorder (optional) Dual IBP Nellcor (optional) |
Store & Reviewing | |
ECG | 30 minutes one important lead's ECG waveform |
Alarm | 1800groups Alarm events reviewing |
NIBP | 400 groups NIBP measurement |
Arrhythmia | 128 groups data (8 seconds ECG waveforms) |
Power | off storage:72 hours trend data & 1 ECG wave form(option) |
ECG | |
Mode | 5-leads (standard);3-leadsor 12-leads (option) |
Lead selection | I, 11, 1H,aVR,aVL,aVF,V1~V6(option) |
Gain | AUTO,0.25x,0.5x,1.0x,2.0x,4.0x -Insulation Breakdown Voltage4000VAC 50/60Hz Sweep speed 6.25mm/s,12.5mm/s,25mm/s,50mm/s |
HR Range | Adult:10~300bpm Child & Neonate:10~350bpm -HRAccuracy ±1%or±1 bpm,whichever is greater |
IBP(option) | |
Channel | 2 |
Measurement Range | -50~+300mmH |
Unit | mmHg,kPa |
Accuracy | ±2mmHgor2%,whichever is greater |
Alarm | |
Three Level | Low, medium and high |
Indication | Auditory and visual |
Setup | Default and custom |
Silence | All alarms can be silenced |
Volume | 45-85 dB measured at 1 meter |
Q 1: Your company is manufacturer or trader?
A 1:We are one industry & Trade company. We have own investment in factory of xray machine, to invest in some good factory to strengh our own product supply chain is our long term strategy.
Q 2: What certificate do you have for products you supply?
A 2: All our products have ISO, 90% have CE, some FDA
Q 3: What is your Warranty for medical equipment?
A 3: Basically 14months after goods leave China. Our own manufactured Xray 24months warranty.
Q 4: What is your acceptable payment way?
A 4: T/T in advance, WEST UNION, MONEYGRAM, and L/C if needed.
Q 5:Can you do OEM for us?
A 5: Yes, we can. Some products with low value need quantity to do OEM.
Q 6: What is your MOQ?
A 6: For common equipment, 1pcs is MOQ. For consumables, we can discuss.